National High-Tech Enterprise · 10+ granted patents · Own fermentation & formulation +86 533 2770005 | sales@z001.com.cn

Product manual

PO Series Odor Control Manual

Industrial deodorization for pulp & paper and beyond — mechanism, model selection, dosing windows and the verification basis behind every claim.

This manual summarizes the PO Series industrial odor-control product line and the W / O methanol and oil-phase odor removers: application scenarios, odour spectra, typical dosing windows, packaging and the verification and compliance basis behind each claim. It is written for plant operators, EPC contractors and importers evaluating a deodorizing programme.

Formulation details, quality-control internals and pricing are not part of this public edition; they are shared under NDA together with TDS / SDS once a specific application is on the table.

Six-layer odour-control mechanism

Masking is the last layer, not the only one. At least three irreversible capture layers are combined in every formulation.

LayerFunctionWhere it works
1 · Source suppressionNitrate / anthraquinone chemistry suppresses sulfate-reducing bacteria and raises redox potentialPO-01S, PO-04 — cuts H₂S generation at source
2 · Chemical captureZinc salts, triazine and ferrous salts bind H₂S, mercaptans and amines into stable, non-releasing compoundsPO-01, PO-01A, PO-05, PO-06
3 · InclusionCyclodextrin cavities trap small odour molecules and lower gas-phase partial pressureAll water-based types, PO-05
4 · Polyphenol complexationPlant polyphenols bind ammonia / amines and slow oxidative odour formationPO-01, PO-02, PO-03, PO-05
5 · Biological degradationMicrobial cultures and enzymes metabolize H₂S, ammonia and VFA into CO₂, water and sulfatePO-04 — long-term, root-cause control
6 · Fragrance modificationIn-house compounded plant fragrance base for immediate perceived reliefFinal layer only — never the sole mechanism
Dosage-form discipline: formulations are split strictly by matrix — water-based for effluent, scrubbers and wet-end systems; anhydrous oil-based for oily sludge, coal tar and bitumen; solid powder for sludge and waste piles; live-microbe liquid for biological treatment. Water-based products must never be added to oily sludge, heavy oil or bitumen — free water causes emulsification, out-of-spec moisture, phase separation and tank corrosion.

Product matrix — PO Series

Eight production models across six product families, typed by odour spectrum and dosing point — no single-product-fits-all.

ModelProductApplication & odour spectrumTypical dosagePackaging
PO-01TRS Odor ScavengerKraft pulping, alkali recovery, effluent plants, scrubber circulation water — H₂S, methyl mercaptan, dimethyl sulfide, DMDSScrubber water 1‰–3‰; effluent 0.05–0.15%25 / 30 kg HDPE drum; 1000 kg IBC
PO-01AHigh-Sulfur Emergency Triazine TypeHigh-sulfur upsets, H₂S excursions — high-concentration H₂S and mercaptans0.1–0.5% (1–5 kg/t water)25 / 30 kg HDPE drum
PO-01SSRB Source-Control InhibitorEqualization, anaerobic / facultative basins, sludge wells — sulfide control at sourceNO₃⁻ target 50 mg/L (0.2–0.4 kg/t water)25 / 30 kg HDPE drum; 1000 kg IBC
PO-02Wet-End & White Water Odor Control AgentWhite-water loops, pulp and machine chests, coater tanks — VFA, slime odour, aminesContinuous 100–300 ppm; PO-02B shock dosing for upsets25 / 30 kg HDPE drum; 1000 kg IBC
PO-03Plant-Based Atomizing Odor NeutralizerWorkshop air, exhaust, scrubbers, sludge dewatering halls, transfer stations — broad mixed odour, H₂S, NH₃, VOCDilute 100–300× for atomization; scrubber first dose 3‰, then 1‰ daily25 / 30 kg HDPE drum; 1000 kg IBC
PO-04Enzyme & Microbial DeodorizerBiological basins, sludge, leachate, composting — H₂S, ammonia, VFA (long-term degradation)Dilute 50–200×; pH 6–9, dissolved oxygen required25 kg HDPE drum (light-protected)
PO-05Slow-Release Deodorizing PowderSludge dewatering halls, stockpiles, waste transfer stations, screenings — slow-release H₂S, ammonia, amines, VFASpread 0.5–2 kg/t material, or hang in permeable bags25 kg woven bag with PE liner
PO-06Anhydrous Oil-Based DeodorizerOily sludge, coal tar, bitumen, heavy fuel oil — mercaptans, thiophenes, pyridines, naphthenic VOC0.10–0.30% (blend at 40–60 °C after viscosity reduction)25 / 30 kg HDPE drum; 200 kg steel drum

Model profiles

Application, odour spectrum, typical dosage and the engineering note behind each model.

PO-01 — TRS Odor Scavenger

Neutral water-based concentrate

Application
Kraft pulping, alkali recovery, effluent plants, scrubber circulation water
Odour spectrum
H₂S · methyl mercaptan · dimethyl sulfide · DMDS
Dosage
Scrubber water 1‰–3‰; effluent 0.05–0.15%
Key point
Zinc coordination + cyclodextrin inclusion capture, quantifiable by detector tubes; neutral, ambient use, no odour rebound

Compliance note: terpene fragrance base — closed-cup flash point measured and transport condition assessment issued before shipping.

PO-01A — High-Sulfur Emergency Triazine Type

Alkaline shock treatment (pH 9–11)

Application
High-sulfur upsets, H₂S excursions in effluent and gas scrubbing
Odour spectrum
High-concentration H₂S · mercaptans
Dosage
0.1–0.5% (1–5 kg/t water)
Key point
HET triazine converts H₂S and mercaptans into stable water-soluble thiazines without scaling; not for neutral-product pipelines

Compliance note: alkaline — full PPE and dedicated storage; never dosed on the same line as neutral products.

PO-01S — SRB Source-Control Inhibitor

Nitrate source-control liquid

Application
Equalization, anaerobic / facultative basins, sludge wells
Odour spectrum
Sulfide · H₂S generated at source
Dosage
NO₃⁻ target 50 mg/L (0.2–0.4 kg/t water)
Key point
Suppresses sulfate-reducing bacteria and raises ORP — cuts H₂S generation at source instead of masking downstream

Compliance note: Class 5 oxidizer — segregated storage away from organics and powders.

PO-02 — Wet-End & White Water Odor Control Agent

Low-foam non-ionic wet-end treatment

Application
White-water loops, pulp and machine chests, coater tanks
Odour spectrum
VFA · slime odour · amines
Dosage
Continuous 100–300 ppm; PO-02B shock dosing for upsets
Key point
Long-term bacteriostatic control plus zinc / tannin complexation of VFA — preserves retention, AKD/ASA sizing, brightness and strength

Compliance note: fragrance-free PO-02N available for tissue and food-contact grades (BIT migration limits checked per destination regulation).

PO-03 — Plant-Based Atomizing Odor Neutralizer

High-dilution water-based microemulsion

Application
Workshop air, exhaust, scrubbers, dewatering halls, waste transfer stations
Odour spectrum
Broad mixed odour · H₂S · NH₃ · VOC
Dosage
Dilute 100–300× for atomization; scrubber first dose 3‰, then 1‰ daily
Key point
Goes beyond masking-only plant liquids: adds cyclodextrin inclusion, zinc capture and tea polyphenols for measurable removal at very low in-use cost

Compliance note: terpene-rich fragrance base — flash point measured; no heating, no mixing with disinfectants.

PO-04 — Enzyme & Microbial Deodorizer

Live-microbe + multi-enzyme liquid

Application
Biological basins, sludge, leachate, composting
Odour spectrum
H₂S · ammonia · VFA (long-term degradation)
Dosage
Dilute 50–200×; pH 6–9, dissolved oxygen required
Key point
Degrades odour compounds instead of masking them; no biocides or preservatives in the formulation; also assists COD / ammonia-nitrogen reduction

Compliance note: live microbial product — never dosed with biocides on the same line; viability stated on the label; export subject to destination bio-safety rules.

PO-05 — Slow-Release Deodorizing Powder

Ready-to-spread solid powder

Application
Sludge dewatering halls, stockpiles, waste transfer stations, screenings
Odour spectrum
Slow-release H₂S · ammonia · amines · VFA
Dosage
Spread 0.5–2 kg/t material, or hang in permeable bags
Key point
Activated zeolite + activated carbon adsorption, ferrous sulfide fixation, cyclodextrin inclusion and microencapsulated fragrance — no spraying equipment needed

Compliance note: never mixed with nitrate oxidizers; dust explosion assessment and moisture ≤5% controlled at works.

PO-06 — Anhydrous Oil-Based Deodorizer

Water-free, high-flash-point oil phase

Application
Oily sludge, coal tar, bitumen, heavy fuel oil
Odour spectrum
Mercaptans · thiophenes · pyridines · naphthenic VOC
Dosage
0.10–0.30% blended at 40–60 °C after viscosity reduction
Key point
High-flash-point carrier (≥130 °C) with oil-soluble zinc capture and asphaltene dispersant — prevents the emulsification and water pickup caused by water-based products

Compliance note: strictly no free water; moisture (Karl Fischer), calorific value and copper-strip corrosion re-checked after dosing.

W / O Series — methanol and oil-phase odor removers

The same capture chemistry typed for methanol, alcohol-based fuels and hydrophobic oil systems.

W-01 — Water-Based Odor Remover (Methanol / Fuel-Grade Alcohols)

Water-based microemulsion, pH 6.5–7.5

Application
Methanol and alcohol-based fuel blending, aqueous systems, oilfield effluent deodorizing
Mechanism
Four-layer: zinc coordination capture + cyclodextrin inclusion + plant polyphenol complexation + plant fragrance modification
Dosage
0.05–0.30% w/w, finalized by on-site jar trials
Key point
Ambient-temperature use, closed-cup flash point target above 60 °C, 24-month shelf life

Methanol-compatible; dosing points and rates confirmed by site trial before fixed supply.

O-01 — Oil-Based (Anhydrous) Odor Remover

High-flash-point anhydrous oil phase

Application
Coal tar, heavy oil, finished fuel products — hydrophobic systems
Mechanism
Oil-soluble zinc capture + self-emulsifying dispersion + plant fragrance modification
Dosage
0.10–0.30%, blended at 40–60 °C after viscosity reduction
Key point
Water-free processing end to end; flash point ≥130 °C carrier prevents emulsification and water pickup

Water-based products must never be substituted in hydrophobic systems — free water causes emulsification, out-of-spec moisture and tank corrosion.

Scenario selection quick reference

Combinations are dosed at split points; every line states how the result is accepted.

Site / pain pointRecommended set-upDosing methodAcceptance basis
TRS exceedance at evaporation / alkali-recovery scrubbersPO-01 + PO-01A (upset backup)Scrubber water 1‰–3‰, metered pump linked to spray≥80% H₂S / TRS removal in exhaust; no scaling or fouling
Odour from equalization, clarifiers and sludge wellsPO-01S + PO-01 / PO-04Split dosing: source control at inlet, capture at outlet≥80% drop in aqueous sulfide; no odour rebound at 24 h
White-water odour, slime, finished-sheet smellPO-02 / PO-02N (fragrance-free)100–300 ppm continuous into machine chestOdour grade down ≥2 levels; retention / sizing / brightness within ±5% of blank
Fugitive odour at dewatering halls and stockpilesPO-05 + PO-03Powder spreading + 200× diluted space atomizationSite-boundary odour compliant with GB 14554; no dust or fragrance overshoot
Broad mixed odour in workshops and scrubbersPO-03 (high-dilution concentrate)Dilute 100–300×, misting every 2–5 min intervals≥80% removal even at 200× dilution; no nozzle blockage
Long-term control in biobasins, leachate, compostingPO-04 + PO-01SDilute 50–200×; pH 6–9, maintain dissolved oxygenOnset at 72 h, sustained over 7 days without rebound; viable cell count on spec
Oily sludge, coal tar, bitumenPO-06 (water-based products prohibited)0.10–0.30% blended at 40–60 °CMoisture, calorific value, flash point and copper-strip corrosion unchanged

Verification & quality basis

Quantified by instrument, not by adjective.

Performance is stated only in measurable terms. The acceptance target used across the series is ≥80% removal of the target odour compound within 30 minutes, measured by detector tube or headspace GC against an untreated blank, with no odour rebound at 24 hours (72-hour evaluation for live-microbe PO-04). Routine batch release covers appearance, pH, density, solids / moisture, centrifugal and cold-hot storage stability; fragrance-bearing models additionally get a closed-cup flash point test per batch family.

Before fixed supply we run an on-site jar / field trial: blank vs. 3–4 dosage gradients, odour intensity scoring by a blind panel, detector-tube quantification, and compatibility checks against the host process (retention, sizing and brightness for wet-end; moisture, calorific value and copper-strip corrosion for oil systems). The lowest dosage that meets the threshold becomes the recommended rate.

Documentation & compliance

Each shipment can be accompanied by: TDS; 16-section GHS-format SDS; closed-cup flash point report; third-party odour-removal test; transport condition assessment (non-restricted confirmation where applicable); and strain identification / non-GMO statements for PO-04.

HS classification is indicative only: wet-end paper chemical aids map to 3809.92, general industrial odor-control preparations to 3824.99 or 3307.49 depending on form and presentation. Final classification follows advance ruling or broker confirmation in the destination country. For EU and US markets we check REACH / CLP status, allergen fragrance labelling and TSCA / DSL inventory coverage per consignee request.

Claims policy: we do not publish unqualified figures such as instant deodorization or fixed percentage removal rates. Every performance statement in this manual is tied to the test method and acceptance basis above.

Evaluating a deodorizing programme?

Send us the odour spectrum, the matrix (water / oil / sludge / air) and the dosing point — we will propose the model combination, a trial plan and the document pack, usually within one working day.