This manual summarizes the PO Series industrial odor-control product line and the W / O methanol and oil-phase odor removers: application scenarios, odour spectra, typical dosing windows, packaging and the verification and compliance basis behind each claim. It is written for plant operators, EPC contractors and importers evaluating a deodorizing programme.
Formulation details, quality-control internals and pricing are not part of this public edition; they are shared under NDA together with TDS / SDS once a specific application is on the table.
Six-layer odour-control mechanism
Masking is the last layer, not the only one. At least three irreversible capture layers are combined in every formulation.
| Layer | Function | Where it works |
|---|---|---|
| 1 · Source suppression | Nitrate / anthraquinone chemistry suppresses sulfate-reducing bacteria and raises redox potential | PO-01S, PO-04 — cuts H₂S generation at source |
| 2 · Chemical capture | Zinc salts, triazine and ferrous salts bind H₂S, mercaptans and amines into stable, non-releasing compounds | PO-01, PO-01A, PO-05, PO-06 |
| 3 · Inclusion | Cyclodextrin cavities trap small odour molecules and lower gas-phase partial pressure | All water-based types, PO-05 |
| 4 · Polyphenol complexation | Plant polyphenols bind ammonia / amines and slow oxidative odour formation | PO-01, PO-02, PO-03, PO-05 |
| 5 · Biological degradation | Microbial cultures and enzymes metabolize H₂S, ammonia and VFA into CO₂, water and sulfate | PO-04 — long-term, root-cause control |
| 6 · Fragrance modification | In-house compounded plant fragrance base for immediate perceived relief | Final layer only — never the sole mechanism |
Product matrix — PO Series
Eight production models across six product families, typed by odour spectrum and dosing point — no single-product-fits-all.
| Model | Product | Application & odour spectrum | Typical dosage | Packaging |
|---|---|---|---|---|
| PO-01 | TRS Odor Scavenger | Kraft pulping, alkali recovery, effluent plants, scrubber circulation water — H₂S, methyl mercaptan, dimethyl sulfide, DMDS | Scrubber water 1‰–3‰; effluent 0.05–0.15% | 25 / 30 kg HDPE drum; 1000 kg IBC |
| PO-01A | High-Sulfur Emergency Triazine Type | High-sulfur upsets, H₂S excursions — high-concentration H₂S and mercaptans | 0.1–0.5% (1–5 kg/t water) | 25 / 30 kg HDPE drum |
| PO-01S | SRB Source-Control Inhibitor | Equalization, anaerobic / facultative basins, sludge wells — sulfide control at source | NO₃⁻ target 50 mg/L (0.2–0.4 kg/t water) | 25 / 30 kg HDPE drum; 1000 kg IBC |
| PO-02 | Wet-End & White Water Odor Control Agent | White-water loops, pulp and machine chests, coater tanks — VFA, slime odour, amines | Continuous 100–300 ppm; PO-02B shock dosing for upsets | 25 / 30 kg HDPE drum; 1000 kg IBC |
| PO-03 | Plant-Based Atomizing Odor Neutralizer | Workshop air, exhaust, scrubbers, sludge dewatering halls, transfer stations — broad mixed odour, H₂S, NH₃, VOC | Dilute 100–300× for atomization; scrubber first dose 3‰, then 1‰ daily | 25 / 30 kg HDPE drum; 1000 kg IBC |
| PO-04 | Enzyme & Microbial Deodorizer | Biological basins, sludge, leachate, composting — H₂S, ammonia, VFA (long-term degradation) | Dilute 50–200×; pH 6–9, dissolved oxygen required | 25 kg HDPE drum (light-protected) |
| PO-05 | Slow-Release Deodorizing Powder | Sludge dewatering halls, stockpiles, waste transfer stations, screenings — slow-release H₂S, ammonia, amines, VFA | Spread 0.5–2 kg/t material, or hang in permeable bags | 25 kg woven bag with PE liner |
| PO-06 | Anhydrous Oil-Based Deodorizer | Oily sludge, coal tar, bitumen, heavy fuel oil — mercaptans, thiophenes, pyridines, naphthenic VOC | 0.10–0.30% (blend at 40–60 °C after viscosity reduction) | 25 / 30 kg HDPE drum; 200 kg steel drum |
Model profiles
Application, odour spectrum, typical dosage and the engineering note behind each model.
PO-01 — TRS Odor Scavenger
Neutral water-based concentrate
- Application
- Kraft pulping, alkali recovery, effluent plants, scrubber circulation water
- Odour spectrum
- H₂S · methyl mercaptan · dimethyl sulfide · DMDS
- Dosage
- Scrubber water 1‰–3‰; effluent 0.05–0.15%
- Key point
- Zinc coordination + cyclodextrin inclusion capture, quantifiable by detector tubes; neutral, ambient use, no odour rebound
Compliance note: terpene fragrance base — closed-cup flash point measured and transport condition assessment issued before shipping.
PO-01A — High-Sulfur Emergency Triazine Type
Alkaline shock treatment (pH 9–11)
- Application
- High-sulfur upsets, H₂S excursions in effluent and gas scrubbing
- Odour spectrum
- High-concentration H₂S · mercaptans
- Dosage
- 0.1–0.5% (1–5 kg/t water)
- Key point
- HET triazine converts H₂S and mercaptans into stable water-soluble thiazines without scaling; not for neutral-product pipelines
Compliance note: alkaline — full PPE and dedicated storage; never dosed on the same line as neutral products.
PO-01S — SRB Source-Control Inhibitor
Nitrate source-control liquid
- Application
- Equalization, anaerobic / facultative basins, sludge wells
- Odour spectrum
- Sulfide · H₂S generated at source
- Dosage
- NO₃⁻ target 50 mg/L (0.2–0.4 kg/t water)
- Key point
- Suppresses sulfate-reducing bacteria and raises ORP — cuts H₂S generation at source instead of masking downstream
Compliance note: Class 5 oxidizer — segregated storage away from organics and powders.
PO-02 — Wet-End & White Water Odor Control Agent
Low-foam non-ionic wet-end treatment
- Application
- White-water loops, pulp and machine chests, coater tanks
- Odour spectrum
- VFA · slime odour · amines
- Dosage
- Continuous 100–300 ppm; PO-02B shock dosing for upsets
- Key point
- Long-term bacteriostatic control plus zinc / tannin complexation of VFA — preserves retention, AKD/ASA sizing, brightness and strength
Compliance note: fragrance-free PO-02N available for tissue and food-contact grades (BIT migration limits checked per destination regulation).
PO-03 — Plant-Based Atomizing Odor Neutralizer
High-dilution water-based microemulsion
- Application
- Workshop air, exhaust, scrubbers, dewatering halls, waste transfer stations
- Odour spectrum
- Broad mixed odour · H₂S · NH₃ · VOC
- Dosage
- Dilute 100–300× for atomization; scrubber first dose 3‰, then 1‰ daily
- Key point
- Goes beyond masking-only plant liquids: adds cyclodextrin inclusion, zinc capture and tea polyphenols for measurable removal at very low in-use cost
Compliance note: terpene-rich fragrance base — flash point measured; no heating, no mixing with disinfectants.
PO-04 — Enzyme & Microbial Deodorizer
Live-microbe + multi-enzyme liquid
- Application
- Biological basins, sludge, leachate, composting
- Odour spectrum
- H₂S · ammonia · VFA (long-term degradation)
- Dosage
- Dilute 50–200×; pH 6–9, dissolved oxygen required
- Key point
- Degrades odour compounds instead of masking them; no biocides or preservatives in the formulation; also assists COD / ammonia-nitrogen reduction
Compliance note: live microbial product — never dosed with biocides on the same line; viability stated on the label; export subject to destination bio-safety rules.
PO-05 — Slow-Release Deodorizing Powder
Ready-to-spread solid powder
- Application
- Sludge dewatering halls, stockpiles, waste transfer stations, screenings
- Odour spectrum
- Slow-release H₂S · ammonia · amines · VFA
- Dosage
- Spread 0.5–2 kg/t material, or hang in permeable bags
- Key point
- Activated zeolite + activated carbon adsorption, ferrous sulfide fixation, cyclodextrin inclusion and microencapsulated fragrance — no spraying equipment needed
Compliance note: never mixed with nitrate oxidizers; dust explosion assessment and moisture ≤5% controlled at works.
PO-06 — Anhydrous Oil-Based Deodorizer
Water-free, high-flash-point oil phase
- Application
- Oily sludge, coal tar, bitumen, heavy fuel oil
- Odour spectrum
- Mercaptans · thiophenes · pyridines · naphthenic VOC
- Dosage
- 0.10–0.30% blended at 40–60 °C after viscosity reduction
- Key point
- High-flash-point carrier (≥130 °C) with oil-soluble zinc capture and asphaltene dispersant — prevents the emulsification and water pickup caused by water-based products
Compliance note: strictly no free water; moisture (Karl Fischer), calorific value and copper-strip corrosion re-checked after dosing.
W / O Series — methanol and oil-phase odor removers
The same capture chemistry typed for methanol, alcohol-based fuels and hydrophobic oil systems.
W-01 — Water-Based Odor Remover (Methanol / Fuel-Grade Alcohols)
Water-based microemulsion, pH 6.5–7.5
- Application
- Methanol and alcohol-based fuel blending, aqueous systems, oilfield effluent deodorizing
- Mechanism
- Four-layer: zinc coordination capture + cyclodextrin inclusion + plant polyphenol complexation + plant fragrance modification
- Dosage
- 0.05–0.30% w/w, finalized by on-site jar trials
- Key point
- Ambient-temperature use, closed-cup flash point target above 60 °C, 24-month shelf life
Methanol-compatible; dosing points and rates confirmed by site trial before fixed supply.
O-01 — Oil-Based (Anhydrous) Odor Remover
High-flash-point anhydrous oil phase
- Application
- Coal tar, heavy oil, finished fuel products — hydrophobic systems
- Mechanism
- Oil-soluble zinc capture + self-emulsifying dispersion + plant fragrance modification
- Dosage
- 0.10–0.30%, blended at 40–60 °C after viscosity reduction
- Key point
- Water-free processing end to end; flash point ≥130 °C carrier prevents emulsification and water pickup
Water-based products must never be substituted in hydrophobic systems — free water causes emulsification, out-of-spec moisture and tank corrosion.
Scenario selection quick reference
Combinations are dosed at split points; every line states how the result is accepted.
| Site / pain point | Recommended set-up | Dosing method | Acceptance basis |
|---|---|---|---|
| TRS exceedance at evaporation / alkali-recovery scrubbers | PO-01 + PO-01A (upset backup) | Scrubber water 1‰–3‰, metered pump linked to spray | ≥80% H₂S / TRS removal in exhaust; no scaling or fouling |
| Odour from equalization, clarifiers and sludge wells | PO-01S + PO-01 / PO-04 | Split dosing: source control at inlet, capture at outlet | ≥80% drop in aqueous sulfide; no odour rebound at 24 h |
| White-water odour, slime, finished-sheet smell | PO-02 / PO-02N (fragrance-free) | 100–300 ppm continuous into machine chest | Odour grade down ≥2 levels; retention / sizing / brightness within ±5% of blank |
| Fugitive odour at dewatering halls and stockpiles | PO-05 + PO-03 | Powder spreading + 200× diluted space atomization | Site-boundary odour compliant with GB 14554; no dust or fragrance overshoot |
| Broad mixed odour in workshops and scrubbers | PO-03 (high-dilution concentrate) | Dilute 100–300×, misting every 2–5 min intervals | ≥80% removal even at 200× dilution; no nozzle blockage |
| Long-term control in biobasins, leachate, composting | PO-04 + PO-01S | Dilute 50–200×; pH 6–9, maintain dissolved oxygen | Onset at 72 h, sustained over 7 days without rebound; viable cell count on spec |
| Oily sludge, coal tar, bitumen | PO-06 (water-based products prohibited) | 0.10–0.30% blended at 40–60 °C | Moisture, calorific value, flash point and copper-strip corrosion unchanged |
Verification & quality basis
Quantified by instrument, not by adjective.
Performance is stated only in measurable terms. The acceptance target used across the series is ≥80% removal of the target odour compound within 30 minutes, measured by detector tube or headspace GC against an untreated blank, with no odour rebound at 24 hours (72-hour evaluation for live-microbe PO-04). Routine batch release covers appearance, pH, density, solids / moisture, centrifugal and cold-hot storage stability; fragrance-bearing models additionally get a closed-cup flash point test per batch family.
Before fixed supply we run an on-site jar / field trial: blank vs. 3–4 dosage gradients, odour intensity scoring by a blind panel, detector-tube quantification, and compatibility checks against the host process (retention, sizing and brightness for wet-end; moisture, calorific value and copper-strip corrosion for oil systems). The lowest dosage that meets the threshold becomes the recommended rate.
Documentation & compliance
Each shipment can be accompanied by: TDS; 16-section GHS-format SDS; closed-cup flash point report; third-party odour-removal test; transport condition assessment (non-restricted confirmation where applicable); and strain identification / non-GMO statements for PO-04.
HS classification is indicative only: wet-end paper chemical aids map to 3809.92, general industrial odor-control preparations to 3824.99 or 3307.49 depending on form and presentation. Final classification follows advance ruling or broker confirmation in the destination country. For EU and US markets we check REACH / CLP status, allergen fragrance labelling and TSCA / DSL inventory coverage per consignee request.
Claims policy: we do not publish unqualified figures such as instant deodorization or fixed percentage removal rates. Every performance statement in this manual is tied to the test method and acceptance basis above.
Evaluating a deodorizing programme?
Send us the odour spectrum, the matrix (water / oil / sludge / air) and the dosing point — we will propose the model combination, a trial plan and the document pack, usually within one working day.