National High-Tech Enterprise · 10+ granted patents · Own fermentation & formulation +86 533 2770005 | sales@z001.com.cn

Technical article

Why Anaerobic Digester Gas Output Falls and What to Check

Falling biogas yield in an anaerobic digester is diagnosed from gas volume, methane content and effluent COD. A culture adds little if the cause is temperature, loading or pH.

Falling biogas output is a symptom, not a diagnosis, and the useful question is whether the cause sits in the process or in the biology. Three measurements settle it: gas volume, methane content, and the effluent COD together with the volatile fatty acid to alkalinity ratio. If temperature, pH and loading are all inside their normal bands and the ratio is climbing, the active population is the thing to look at. If any of those process parameters has moved, a culture will not fix it, because it would only be adding organisms to a reactor that is operating outside its window.

This note is written for the operators of anaerobic digesters and the engineers who support them, in municipal plants, food processing, abattoirs and industrial anaerobic treatment. It covers what the anaerobic stage actually does, how to read the three measurements, what a culture can and cannot fix, and what to record so that the next adjustment is based on evidence rather than on the last thing that was tried.

Product referenced in this article

Wastewater Treatment Bacteria Culture JY-AO2-02 — application notes, specification table and document downloads for this range.

What the anaerobic stage is actually doing

Anaerobic treatment is usually described as converting organic matter into biogas, which is true but too coarse to be useful when something goes wrong. Underneath, four processes have to run in sequence, and each has its own conditions and its own failure modes.

Hydrolysis and acidification break large molecules — protein, polysaccharide, fat — down into smaller organic acids. This is often the rate-limiting step, and it is sensitive to temperature and to retention time. A reactor that is too cold or too short on retention time simply cannot liberate substrate fast enough for the rest to work.

Acetogenesis converts the smaller acids into acetate, hydrogen and carbon dioxide. Methanogenesis then converts acetate and hydrogen into methane and carbon dioxide, and this is where the actual energy value of the gas comes from. It is also the most sensitive step: methanogens have a narrow pH range, they grow slowly, and they are the first to be inhibited by the compounds that arrive with industrial feed.

Alongside these sits the physical requirement that the biomass stays in the reactor. Granular sludge in an IC or EGSB reactor, or a stable sludge blanket in a UASB, has to be retained while gas rises through it. A reactor producing gas perfectly well but losing its sludge is a reactor that will stop producing gas.

The three measurements that narrow the diagnosis

Before anything is added to a digester, three numbers do most of the work.

Gas volume is the primary signal. Daily production normalised against the organic load applied is more informative than the raw volume, because a fall in feed strength will produce a fall in gas without anything having gone wrong biologically.

Methane content qualifies that signal, but it has to be read carefully because it is a ratio. The methane fraction can rise for two opposite reasons: methanogenesis can slow down while the carbon dioxide produced alongside it drops faster, which happens in an acidifying reactor, or it can rise because the gas has genuinely become more combustible. The distinction is made by reading it against the absolute gas volume, never on its own. A falling methane fraction with falling volume usually indicates that sulphate-reducing organisms are taking over.

Effluent COD and the volatile fatty acid to alkalinity ratio tell you whether the feed is actually being converted. Rising volatile fatty acids with falling alkalinity is the classic early warning of an imbalance between acid production and methanogenesis, and it is visible before the gas output changes. Alkalinity in this context is a buffer: it is what absorbs the acidity produced, and a reactor that has spent its buffer has no margin left to absorb a further load increase.

These three, read together, will usually identify the category of the problem before any product is considered.

What a culture can fix, and what it cannot

This is where the commercial temptation and the engineering reality diverge, so it is worth being plain about it.

A digester culture is a living population of anaerobic organisms. Adding it makes sense when the reactor's operating parameters are already correct and the remaining deficiency is biological: the active population has been reduced by a washout, by a prolonged shock, by a sudden feed change, or by sludge loss from the reactor. In that situation, restoring the population faster than it would re-establish on its own is a genuine advantage, because methanogens grow slowly and a reactor that has lost them recovers slowly by default.

Adding a culture makes very little sense when a process parameter is out of range. If the reactor has been running below its temperature threshold for a month, more organisms will not change the temperature. If the feed is heavily overloaded and the pH has drifted, adding biomass increases the oxygen demand downstream and the acid load without touching the cause. If hydrogen sulphide is rising because the feed now carries more sulphate, the answer is in the feed.

There is a second category worth naming: digester odour. Our anaerobic reactor culture addresses organic breakdown and hydrogen sulphide odour in the anaerobic stage, and it is useful in a reactor whose parameters are sound but whose population has been displaced. It is not a substitute for reducing sulphate in the feed.

Two different products for two different objectives

Once the diagnosis points at biology, it is worth being precise about what the objective is, because the two anaerobic products we supply address different things.

Where the objective is organic breakdown and odour control in the anaerobic stage, the anaerobic reactor culture is the relevant product. It works with the native population of the plant rather than replacing it, which matters in a reactor where the existing granulation is worth preserving.

Where the objective is raising gas yield and lowering effluent COD, the anaerobic biogas culture is the one to look at. It suits UASB, EGSB and IC reactors, it reduces the residual sludge the process leaves behind, and it raises the quantity of usable gas rather than only the condition of the reactor. For a site that is paid on the energy value of the gas it produces, that distinction is the whole decision.

Neither product is a substitute for process optimisation. Anaerobic performance is governed by temperature, retention time, feed characteristics and alkalinity, and all four have to be right before biology becomes the limiting variable.

What to record so the next adjustment is evidence-based

Anaerobic systems adjust slowly, and without a record of what was tried it is easy to keep repeating the same intervention. Four groups of data are worth keeping.

  • Gas side: daily volume, production rate per unit organic load applied, methane fraction, and hydrogen sulphide in the gas;
  • Water side: influent COD, effluent COD and the removal across the stage, volatile fatty acid to alkalinity ratio, ammonia, pH and temperature;
  • Sludge side: sludge concentration, the volume and condition of the sludge blanket or granule bed, and any recorded sludge loss or flotation;
  • Interventions: every dose, every feed change, every load increase, each with its date, and the observed change in the four groups above.

With those four lines aligned, a specific question becomes answerable: was the last improvement produced by correcting the process, or by adding biology? The answer determines what happens the next time the same symptom appears.

For operators who want a second opinion on a specific reactor, our anaerobic biogas culture product page carries application notes, and we are glad to work through reactor type, operating data and current feed with our technical team rather than offer a general recommendation.

Frequently asked questions

What causes biogas yield to fall in an anaerobic digester?
The common causes are a change in temperature, a change in organic loading, pH drifting outside the methanogenic range, inhibitory compounds arriving with the feed, and loss of the active biomass itself. The first four are process conditions that a culture cannot fix, because adding biology to a reactor operating outside its operating window only creates more organisms in the wrong place. Loss of biomass through washout or sludge flotation is the one case where the biology is genuinely the missing element.
How do I tell whether the problem is the process or the biology?
Check three measurements before reaching for any product. Gas volume tells you whether output has fallen. Methane content tells you whether the gas has changed quality, which distinguishes methanogenesis slowing from a simple dilution of the gas by hydrogen sulphide or carbon dioxide. Effluent COD and the volatile fatty acid to alkalinity ratio tell you whether the feed is being converted. If pH, temperature and loading are all within their normal bands and the ratio is climbing, the biology is the thing to look at.
Does raising the methane fraction mean the digester is working better?
Not necessarily, and this is a common misreading. The methane fraction is a ratio, so it can rise because the carbon dioxide component fell even when total gas production did not improve, and a digester that is acidifying often shows a rising methane fraction while its output declines. Read the methane fraction together with the absolute gas volume and never on its own.
When does a digester culture actually help?
When the process conditions are already right and the remaining gap is biological. That typically means the active population has been reduced by a washout, a prolonged shock, a sudden feed change, or sludge loss from the reactor, and the operating parameters are otherwise correct. In that case a culture targeted at the anaerobic stage helps the population re-establish faster than it would on its own, particularly after a long period of unstable operation.
How long does it take to restore gas output after dosing an anaerobic culture?
It depends on how much biology is missing and how stable the process is afterwards. A reactor that was operating within its parameters and suffered a biological setback can recover in a matter of weeks. A reactor whose granules have been damaged or whose loading has been unstable for months takes considerably longer, and the recovery follows the process corrections rather than the dosing. The right measure is the trend in daily gas volume and effluent COD over several operating cycles, not a single week.
Why does an anaerobic reactor start smelling of hydrogen sulphide?
Hydrogen sulphide appears when the balance between sulphate-reducing organisms and methanogens shifts, and sulphate-reducing bacteria outcompete methanogens for the available hydrogen and organic substrate. Common triggers are a high sulphate load in the feed, a retention time that has become too short, and an organic overload that has pushed the reactor towards acid production. The odour is usually a symptom of the balance having moved rather than the cause in itself, so it is worth checking sulphate loading and retention time before treating the odour alone.