National High-Tech Enterprise · 10+ granted patents · Own fermentation & formulation +86 533 2770005 | sales@z001.com.cn

Technical article

Anammox: Where It Fits in Nitrogen Removal and Where It Does Not

How anammox nitrogen removal wastewater fits partial nitritation, why nitrite and temperature decide start-up, and when a conventional train is better.

Partial nitritation and anammox remove nitrogen without the organic carbon demand of conventional denitrification. The saving is real, but the difficulty moves into process control: nitrite has to be produced and held, temperature has to stay favourable, and start-up is long. For most plants with a total nitrogen problem, the carbon and recycle balance is still the first place to look.

This note is for operators and design engineers weighing whether an anammox route is realistic for a given stream. It sets out what the process skips, which conditions decide whether it can be held, and why a conventional denitrifying culture is a different tool rather than a competing product.

Product referenced in this article

Wastewater Treatment Bacteria Culture JY-C003 — application notes, specification table and document downloads for this range.

What the anammox route actually skips

In a conventional train, ammonium is oxidised all the way to nitrate in the aerobic stage, and nitrate is then reduced to nitrogen gas in the anoxic stage using organic carbon as the electron donor. That carbon is often purchased and dosed, which is why total nitrogen compliance carries a visible operating cost.

Anammox organisms use ammonium as the donor and nitrite as the acceptor, producing nitrogen gas directly. Only part of the ammonium needs to be oxidised first, so aeration demand falls and no external carbon is needed for the reduction step. The chemistry is attractive. The control burden it creates is the part that decides whether a project succeeds.

Partial nitritation is the hard half

Before anammox can work, roughly half the ammonium must be oxidised to nitrite and the oxidation must stop there. Nitrite-oxidising organisms have to be suppressed without also suppressing the ammonium oxidisers. Dissolved oxygen, solids retention time, temperature and the free ammonia concentration are the levers, and they interact.

A plant that has spent years stabilising full nitrification is being asked to run a deliberately incomplete one. Our note on why ammonia removal fails in a biological plant covers the diagnostic side of that population, and our JY-C002 nitrifying culture is used where the aerobic stage needs its nitrifiers restored rather than partially suppressed.

Nitrite is both substrate and inhibitor

Nitrite is the feed for the anammox step and, above a certain concentration, an inhibitor of the same organisms. A small imbalance in the partial nitritation stage therefore produces either starvation or toxicity. Nitrate appearing in the effluent is a useful warning that the oxidation has gone too far.

This is why the route needs continuous measurement rather than a weekly laboratory result. The ratio of nitrite to ammonium at the anammox inlet, pH and alkalinity, and the nitrate produced all have to be read together. A control strategy built on a single dissolved oxygen setpoint rarely holds through a load change.

Temperature and the long start-up

Anammox organisms grow slowly and are easily washed out, so the reactor must retain biomass well and the population has to be built from a suitable seed. Warm, concentrated side streams give the best chance; cooler mainstream wastewater makes both the rate and the stability harder to hold.

Start-up is therefore a commissioning project measured in months, not a dose added to an existing tank. Our note on wastewater bacteria in cold-climate operation sets out how temperature shifts the nitrifying population generally. A nitrite accumulation or a pH excursion during start-up can set the timeline back by weeks.

Where the route fits

The strongest case is a warm stream with high ammonium and little readily degradable organic carbon: sludge dewatering liquor, certain anaerobic digester effluents, and some industrial side streams. There the carbon saving is large, the load is steady, and the side stream can be treated separately without risking the main plant.

A dedicated reactor with good biomass retention, reliable instrumentation and an operator able to hold a narrow control window is also part of the fit. Where those conditions exist, the route can reduce both aeration and purchased carbon. Where they do not, the same chemistry becomes a source of recurring instability.

Where it does not fit

A variable influent, a low or widely swinging temperature, a high organic carbon load, or a plant without the instrumentation and staffing to manage nitrite are poor candidates. Readily degradable carbon favours ordinary heterotrophic denitrification and competes with the autotrophic population the route depends on.

Nor is anammox a quick fix for a plant that is already missing its total nitrogen limit. If the anoxic zone is carbon-starved or the internal recycle is undersized, correcting those is faster and more predictable. Adding tank volume does not fix a missing electron donor, and neither does changing the biology.

Why a denitrifying culture is a different process

We do not supply an anammox seed. Our JY-C003 denitrifying culture is applied in the anoxic stage of a conventional nitrogen removal train, where it converts nitrate to nitrogen gas using available carbon. JY-C002 restores the nitrifying population in the aerobic stage. They are tools for the conventional route, not substitutes for an anammox reactor.

Being clear about that boundary matters. A supplier who describes a conventional denitrifying culture as an anammox product has conflated two different processes with different organisms, different start-up times and different control needs. A plant considering anammox needs a specialist seed and a dedicated process design.

What to measure before deciding

Build a nitrogen balance first: influent ammonium and total nitrogen, the COD to nitrogen ratio, temperature range, pH and alkalinity, dissolved oxygen in the aerobic stage, anoxic volume and internal recycle rate, and the permit limit. Then read nitrate and nitrite trends across several weeks rather than a single sample.

If nitrite seldom appears and nitrate tracks the ammonium load, the plant is running full nitrification and the question is carbon and recycle. If nitrite is already accumulating, the cause may be an unbalanced aerobic stage rather than an anammox opportunity. The two readings lead to completely different projects.

What you observeWhat it usually points toFirst thing to check
Nitrite accumulatingPartial oxidation out of balanceAeration, SRT, DO
Nitrate rising insteadOver-oxidation to nitrateDO setpoint, oxidisers
Slow start-up, no rateTemperature, biomass lossTemperature, seed source
Ammonia breakthroughActivity suppressedNitrite ratio, pH, alkalinity
High carbon in feedWrong route for anammoxInfluent COD to N ratio
Stable TN, high costCarbon dose oversizedCarbon balance, recycle

What to send us before specifying

A useful enquiry starts with the train and the nitrogen balance, not with a product name. Include the stream type and flow, average and peak ammonium, COD to nitrogen ratio, temperature range, pH and alkalinity, aerobic and anoxic volumes, internal recycle rate, the permit limit, and a composite record over one load cycle.

Our application engineers use that to say whether the conventional route is the right one, which operating condition needs attention first, and what must be confirmed before dosing. Our guide to bacteria dosing and our notes on choosing a wastewater bacteria culture cover the practical decisions around introduction and selection.

Frequently asked questions

Why is anammox described as a carbon-saving route?
Conventional denitrification needs an electron donor, usually organic carbon, to reduce nitrate to nitrogen gas. Anammox organisms use ammonium as the donor and nitrite as the acceptor, so no external carbon is needed for that step and less aeration is required because only part of the ammonium is oxidised first. The saving is real, but it moves the difficulty into process control.
What is partial nitritation and why is it difficult?
It is the first step: oxidising roughly half the ammonium to nitrite while stopping there, instead of continuing to nitrate. That means suppressing nitrite-oxidising organisms without also suppressing the ammonium oxidisers. Dissolved oxygen, sludge age, temperature and the waste stream chemistry all have to be held in a narrow balance, and the balance shifts with the load.
Can anammox treat an ordinary municipal or industrial wastewater?
Usually not as a straight replacement. The route works best on warm, high-ammonium, low-organic streams such as sludge dewatering liquors or certain industrial side streams. Mainstream application at lower temperature and with a variable carbon load remains harder to hold stably. Where total nitrogen is the problem in a conventional plant, a carbon and recycle audit comes first.
Why does anammox start-up take so long?
Anammox organisms grow very slowly and are easily washed out, so the reactor has to retain biomass extremely well and the population has to be built from a suitable seed. Temperature changes, nitrite accumulation and a pH shift during that period can set the start-up back by weeks. It is a commissioning project with its own timeline, not a product that is dosed into an existing tank.
Does 91bio supply an anammox culture?
No. We supply conventional nitrifying and denitrifying cultures, not an anammox seed. JY-C003 is a denitrifying culture for the anoxic stage of a conventional nitrogen removal train, and JY-C002 restores the nitrifying population in the aerobic stage. If a plant is considering an anammox route, it needs a specialist seed and a dedicated process design; our cultures serve the conventional route.
What information do you need before recommending a culture?
The nitrogen balance and the train: influent ammonium and total nitrogen, COD to nitrogen ratio, temperature range, pH and alkalinity, dissolved oxygen in the aerobic stage, anoxic volume and internal recycle rate, the permit limit, and the nitrate and nitrite trend across several weeks. A composite record over a load cycle is more useful than a single careful sample.