Produced water sulphate reducing bacteria are the usual reason a produced water system sours. Where sulphate, an attached surface and enough residence time coincide, they convert sulphate to sulphide, and that sulphide reaches the gas stream as hydrogen sulphide and sets up localised corrosion under deposits. The risk can be managed, but it is not managed by biocide alone, and it is judged on the water handling system rather than on the reservoir.
This note is written for production engineers and for the service companies who support them, on the specific question of what to do when a produced water system starts producing hydrogen sulphide, or when corrosion coupons come back with pitting under the deposit. It treats produced water as its own environment, separate from the reservoir and separate from the injection programme, because the organisms that cause trouble there are governed by the water handling system rather than by the rock.
Product referenced in this article
Bio-based Oilfield Additive for Viscosity Reduction and Wellbore Cleanup — application notes, specification table and document downloads for this range.
What produced water is, and why it suits sulphate reducers
Produced water is the formation water that comes up with oil or gas. It is typically far more saline than seawater, it carries dissolved sulphate picked up from the reservoir rock, and it arrives hot or cold depending on the field. It often holds little free organic carbon, and it frequently sits in tanks, chokelines and separators for hours before it is reinjected, disposed of, or lifted.
That combination is close to ideal for sulphate-reducing bacteria. Sulphate is present, there are surfaces to attach to, trace carbon is usually available, and the residence time in the tanks is long enough for a population to establish. Underneath a deposit the conditions are anaerobic, and that is exactly where the reduction reaction runs.
What souring actually costs
Souring is the visible half of the problem. Hydrogen sulphide leaves the water phase and travels with the gas, so it appears in the separator gas, at the wellhead, in the gas handling equipment and eventually in the gas sold. Where it reaches a low-pressure or vented system it becomes a safety and odour issue before it becomes a production one.
The hidden half is corrosion. Sulphide itself is not the corrosive agent. What matters is that sulphide in water under a deposit creates a local environment in which steel loses its protective film and pits. The pitting shows up on the water side of a separator, on a choke, or in the lines that hold the deposit, and it frequently appears long after the souring was first noticed.
Why biocide-only programmes struggle here
The usual reason is that a biocide dosed into bulk water does not reach the organisms that matter most. Sulphate-reducing bacteria live attached to steel and embedded in the biofilm layer under scale, sand, wax and corrosion product. A treatment that circulates through the bulk phase reaches the water and very little else.
Two further effects work against a biocide-only programme. Residual oxidant is consumed by whatever is in the water, including oil, iron and other reducing species, so the concentration actually experienced at the deposit can be far below what is dosed. And once a population has been removed, the surface remains, so regrowth follows the next production cycle unless something about the system has changed.
Deposits are the control point
This is the practical consequence of the previous section. Deposit management is the part of a control programme that actually reaches the organisms, because removing scale, sand and wax removes the habitat itself. Pigging or flushing a line that has never been cleaned does more for souring than repeated biocide treatments in the same line.
Deposits arrive from the reservoir, from corrosion of the facility, and from the incompatibility between produced water and the chemicals used to treat it. Each source has a different remedy and none of them is a biocide. The first question to ask about any recurrent souring is whether the deposit has ever been looked at.
The monitoring set that makes the risk visible
Monitoring a produced water system for souring risk is a short list and does not need exotic equipment. The readings below are the ones that normally settle an argument about whether a system is souring, and they separate a chemical carry-over problem from a microbial one.
Read together, they also show whether a treatment is working or merely being repeated, which is the harder question and the one that decides whether the next cycle should be funded.
| Reading | What it tells you | What it cannot tell you |
|---|---|---|
| Sulphide in the water phase | Active reduction is occurring | Where the activity sits |
| Hydrogen sulphide in separator gas | Souring has reached the gas stream | Which vessel is the source |
| Sulphate in produced water | Whether the electron donor is present | Whether organisms are active |
| Corrosion coupons and probes | Net metal loss and pitting | The biological cause of it |
| Deposit inspection | Whether habitat is being maintained | What created the deposit |
| Temperature and residence time | Whether conditions allow activity | Whether activity is occurring now |
Produced water and the injection programme are different problems
There is a trap that catches experienced operators. Reservoir souring and produced water souring are related but not the same, and they are usually handled by different teams. A reservoir that has gone sour is a reservoir-wide problem governed by sulphate breakthrough and by the microbial population in the formation. A produced water system that has gone sour is a facility problem governed by deposits, temperature and residence time.
Our note on microbial corrosion in oil and gas systems covers the general mechanism of microbially influenced corrosion and the monitoring discipline behind it. This note stays on the facility side of that line.
Where a bio-based programme fits, and where it must not
This is where an honest answer matters, because biology is now a common word in oilfield services and is applied to problems it does not solve. A biological product can compete for sulphate in a system whose conditions support it. It can also be precisely the wrong thing to add to a system whose difficulty is already uncontrolled microbial growth.
Our bio-based oilfield additive is a viscosity-reduction and wellbore-cleanup product for mature, water-sensitive reservoirs. It is not a souring-control product and is not sold as one. When a customer brings a produced water souring problem, the first answer is usually a deposit and a residence-time problem, and the first recommendation is usually physical.
The exception is the reinjection case. Where produced water is reinjected and the formation is receiving a biological programme, the added organisms do reach the reservoir, which is a reservoir decision with reservoir criteria. Where that reinjected water has to be thickened to control channeling across the pattern, the relevant product is a salt- and heat-tolerant thickener such as our HL biopolymer, and where the reservoir itself is the target, the question is the one covered in microbial enhanced oil recovery and in the choice of a microbial oil displacement agent.
A practical sequence for a souring system
The order below is what a facility engineer can act on without waiting for a laboratory result. It moves from the cheapest and most reversible actions to those that need a shutdown, and it front-loads the checks that are usually skipped. Nothing in the sequence requires a product, and nothing in it should be skipped because a product is already on order.
The point of the sequence is that a treatment is only worth running once the cause has been identified. A biocide programme on a system whose deposits were never cleaned is an expensive way to watch a hydrogen sulphide reading fall with production and rise again with the next cycle.
What to send before anything is specified
When a souring problem is brought to us, the data that decides whether a biological route applies at all is short. The water analysis including sulphate and sulphide, the operating temperature, the residence time in each vessel, the deposit history, the biocide programme with its residual and dosing points, and the corrosion record are enough to start.
With those figures the conversation is about the system. Without them it is about a product, which is the wrong way round. The same applies to a reinjection case, where the reservoir data and the facility data have to be kept apart rather than merged into a single file.
Frequently asked questions
- Are sulphate-reducing bacteria the same thing as souring?
- Souring is the result; sulphate-reducing bacteria are the most common cause. The bacteria reduce sulphate to sulphide under anaerobic conditions, and the sulphide leaves the water and enters the gas stream as hydrogen sulphide. Souring can also come from elsewhere, such as a change in reservoir gas contact, a formation that already carries sulphide, or chemical carry-over from the injection stream, which is why a souring result is confirmed rather than assumed.
- Can biocide treatment alone control souring in produced water?
- Usually not on its own. The organisms of concern are attached to steel and embedded in deposits, where a bulk treatment does not reach, and residual oxidant is consumed by oil, iron and other reducing species before it acts. Biocide dosing works best as part of a programme that also removes deposits and controls residence time, rather than as a substitute for them.
- What is the first thing to check when hydrogen sulphide appears?
- Start with the deposit history and the water analysis. Check whether the affected vessel or line has been cleaned recently, and get sulphate and sulphide figures for the water phase along with hydrogen sulphide in the separator gas. A souring that arrives with a deposit history and rising sulphide points at the facility, while a souring with no deposit change and falling sulphate points at the reservoir.
- Does adding a biological product make souring worse?
- It can, and that is worth answering before anything is injected. A biological product added to a system that already supports uncontrolled microbial growth may add to that population rather than compete with it. The bio-based additive described on this site is a viscosity-reduction and wellbore-cleanup product for mature reservoirs, not a souring-control product, and it is not recommended for a facility with an active souring problem.
- How is produced water souring different from reservoir souring?
- They are governed by different conditions and are usually owned by different teams. Reservoir souring follows sulphate breakthrough and the microbial population in the formation, so it is a reservoir-wide question. Produced water souring follows deposits, temperature and residence time in the facility, so it is a containment question. The two need separate criteria and separate evidence.
- What data is needed before specifying a treatment for souring?
- Send the water analysis with sulphate and sulphide, the operating temperature, the residence time in each vessel, the deposit history, the current biocide programme with its residual and dosing points, and the corrosion record including any coupons or probes. Those figures decide whether a biological route applies at all, or whether the answer is a cleaning schedule and a change of operating practice.